Legrand RC3APTCBK Manual do Utilizador Página 3

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 6
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 2
3
Step 10. Wire and snap communication Step 11. Insert blanking plugs or neoprene foam
jacks in adapters as shown. block in unused communication ports.
NOTE: To maintain UL Fire Classification, all communication modules or blank inserts (factory or customer supplied) must be UL Listed
communication circuit accessories, and must fit securely in the supplied communication brackets with no visible openings between
the module and bracket. Supplied foam plugs must be used when passing cables through the communication openings.
Step 12. Snap communication jacks or Step 13. Align gasket over receptacle and press
communication port plugs into flange. bead into flange channel.
CAUTION: Gasket must be set in place to provide scrub water seal.
Point Keystone Tab
Away From Bezel.
TracJack Blank (Supplied)
CAUTION: Empty communication ports must be closed off
with foam plugs or TracJack blanks to maintain
fire classification.
Foam Plug (Supplied)
TracJack Sold Separately
Communication Jack
Sold Separately
Ortronics Series II Bezel
and Communication Jack
(Series II Bezel Included;
Series II Modular Inserts
Sold Separately)
Point Keystone Tab
Away From Bezel.
Lower Level Bezel Installation
(Typical for Fiber Installations)
Fiber Jack Sold Separately
Pass & Seymour Activate
Bezel and Communication
Jack (Supplied with
RC3ATC and RC3CTC Units)
Point Keystone Tab
Away From Bezel.
Vista de página 2
1 2 3 4 5 6

Comentários a estes Manuais

Sem comentários