DS4015 Tee Fitting
INSTALLATION INSTRUCTIONS
Installation Instruction No.: 43270 – January 2006
Wiremold / Legrand Electrical Systems conform to and should be
installed and properly grounded in compliance with requirements
of the current National Electrical Code, Canadian Electrical
Code, or codes administered by local authorities.
All electrical products may represent possible shock or fire
hazard if improperly installed or used. Wiremold electrical
products are UL listed to U.S. and Canadian safety
standards, made for interior use only, and should be installed
in conformance with current local and/or the National
Electrical Code.
j
Step 1. Mount DS4015 Base to wall using
minimum #8 fasteners as shown.
Step 2. Install Adjust-to-Fit
Couplings to mate with Raceway
Base. Align screws to Tabs as shown.
Step 3. Assemble the Internal Tunnel as shown and mount to the top or bottom Channel. Secure the Internal Tunnel
with supplied screws to the appropriate holes. Make sure End Stops match the Raceway Cover orientation.
Install Radius Control Inserts as shown.
Maximum
4" [102mm]
gap allowed.
Align with Tab
For more information, visit www.wiremold.com/ds4000.
Set Screw
Tab
Set Screw
Tab
NOTE: The DS4015 Tee Fitting can be configured two different ways depending on where the communication
cables are installed. Electrical wiring is meant to be housed inside the Internal Tunnel. Communication
cables are controlled by the Radius Control Inserts.
Snap
Radius
Insert
Radius Control
Insert with
Screw
End
Stops
Internal
Tunnel
Internal
Tunnel
End
Stops
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - DS4015 Tee Fitting

DS4015 Tee FittingINSTALLATION INSTRUCTIONSInstallation Instruction No.: 43270 – January 2006Wiremold / Legrand Electrical Systems conform to and sh

Página 2

COVER INSTALLATION: Hook corners as shown and snap into place.ELECTRICAL WIRING – Top Channel.COMMUNICATION CABLING – Top Channel

Página 3

Cover Removal with 650RTFITTING COVER REMOVAL – Fitting Cover can be removed using two methods:Cover Removal with ScrewdriverStep 1. Locate Dimple on

Página 4

Wiremold / LegrandU.S. and International: 60 Woodlawn Street • West Hartford, CT 061101-800-621-0049 • FAX 860-232-2062 • Outside U.S. 860-233-6

Comentários a estes Manuais

Sem comentários